statistiche web
This site uses cookies only technical. For more information read below information on the page. Click the X to not see this written ... more
OM Power Remote Control OM2500A

GENERAL DESCRIPTION:

Remote Control extends the possibilities of using the OM2500A up to 10 meters away from its operating position. When necessary, you can also connect the remote control unit to the LAN and control it using a special software (which is not part of this package) for unlimited distance.

The package includes:

- OM2500A remote control;

- Power supply 230V / 12V, 600mA;

- 10m patch lead to connect;

- Remote control with OM2500A PA;

 

LABEL DESCRIPTION:


- ON / OFF: Standard ON / OFF switch. The state is indicated by a green LED on the switch;

- FUNCTION: The button controls the PA state of operation. When I have noperating green LED mode is the lid;

- POWER: The power LED indicates the power connection. 12V / 500mA;

- FAULT: Red led error indicates PA fault. It will cover any condition of failure;

- WARNING : Yellow LED indicates PA State Stadby;

- TUNE: Yellow LED will be cover if PI tuning circuitry indicates that additional tuning is required;

- GRID: Indicates 2nd protection grid. Bursted if the current security screen has been reached);

- SWR: Yellow LED will indicate excessive reflected power on the PA antenna jack;

- DRIVE: It will be a lid if the maximum unit power has been exceeded;

- POWER OUTPUT: 30-segment bar graph will indicate peak output power;

- Wires: Standard RJ45 connector - LAN interface for remote access;

- ON: - General Switch ON / OFF. (Supply off 12V per cut per unit);

- DC 12V: Power Jack (5.5 / 2.1) for supplying 12 V / 600 mA;

- CAL: Calibration potentiometer (if necessary to synchronize bar graph with bar graph on OM2500A);

- PA: Direct connection to OM2500A PA

 

WARNING : Please pay attention to not using PA socket as a LAN socket as malicious voltages could damage Ethernet devices such as switches, PCs etc. Use 10m cable only supplied to connect your PA with the remote control unit.

 

The remote control unit must be properly grounded! Connect the screw on the back panel of the box to the local earthing system with a copper cable; use a section of 4 mm2 at least. Connect the transceiver and amplifier to the same earthing system of your cabin carefully! If you are using a higher output power amplifier, you need to be aware that the grounding system works properly. All parts must be grounded on the same system. Use short cables and make sure there are good contacts! Otherwise there is a risk of damage to the equipment, having problems with TVI / BCI or the signal may be distorted.

 

 

INSTRUCTIONS :

- Connect units with the OM 2500A PA using the supplied cable;

- 12V DC supply voltage to the power supply via the supplied power supply;

- Verify that the green POWER LED and the yellow STBY LED are both covers;

- There must be no connection fault will be indicated by sequenced POWER and STBY flashing and status of the lights will be covered constantly;

- Turn on the PA to use the ON button;

- The heating process of the hose will start. This will be indicated by the LED on the green ON button and the flashing of the four LEDs (TUNE, GRID, SWR, DRIVE) (wait LED will also be a cover on the PA front panel;

- After the PA heating process is now ready to be transformed into operating mode using the OPERATE button;

- Use the same switch to enter STBY / use (it works as zeroing has failed to occur);

 

LAN CONNECTION

Remote unit interface to the LAN via XPORT made by Lantronix (type XP1001000-05R). More information is available at www.lantronix.com

 

XPORT FACTORY SETTINGS ARE :

- IP address : 192.168.1.222 (first series can be: 192.168.1.101);
- Mask : 255.255.255.0;
- Gateway : 192.168.1.1;

These are the default settings. You can edit any of these by going to the XPORT GUI web through your web browser. It is advisable not to change other parameters of the XPORT interface the loss of communication can be caused by this way. There is no user name or default password. We strongly recommend that you provide a web interface with username and password.

For remote control and monitoring on a special LAN software is required. It is available for free; can be downloaded from the following address: http://www.om-power.com/download

Write a review

Note: HTML is not translated!
    Bad           Good

Captcha

OM Power Remote Control OM2500A

WhatsApp +393331832811

Estimated Delivery (3-4 Working Days)

  • Brand: OM-Power
  • Product Code: OM-2500AREM
    Non in magazzino, verrà ordinato solo su richiesta, deposito cauzionale richiesto, tempi di conseg
  • Availability: In Stock
  • 348,99€
  • Ex Tax: 286,06€

Authorized dealer